WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
1F80-24
Programmable Electronic Digital Thermostat
INSTALLATION AND
OPERATION INSTRUCTIONS
Printed in U.S.A.
PART NO. 37-5287E
Replaces 37-5287D
9901
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
Your new White-Rodgers Digital Thermostat uses the technol-
ogy of a solid-state microcomputer to provide precise time/
temperature control. This thermostat offers you the flexibility to
design heating and cooling programs that fit your needs.
Features:
Battery powered (3 “AA” Energizer
®
alkaline batteries in-
cluded)
Same program for all days of the week
Simultaneous heat and cool program storage
Four separate time/temperature settings per program
Preprogrammed temperature control
LCD continuously displays set point, and alternately dis-
plays time and room temperature
Temperature override until next program period
Manual program override (HOLD temperature)
User may select either 12- or 24-hour clock display
°F/°C convertibility
Temperature range 45° to 90°F
Standard five terminals for single or dual transformer
systems
B & O terminals for single stage heat pumps or damper
operation
WHITE-RODGERS
SPECIFICATIONS
ELECTRICAL DATA
Electrical Rating:
8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-40°F to 150°F
APPLICATIONS
For use with:
Standard heat/cool or heat only systems
Electric heat systems
Gas or oil fired systems
Gas systems with intermittent ignition devices (I.I.D.) and/
or vent dampers
Hydronic (hot water or steam) systems
Single-stage heat pump systems
Millivolt systems
DO NOT USE WITH:
Multi-stage systems
Systems exceeding 30 VAC and 1.5 amps
3-wire zoned hydronic heating systems
PRECAUTIONS
Operator: Save these instructions for future use!
This thermostat is intended for use with a low voltage system; do
not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contractor
or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes and
ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
To prevent electrical shock and/or equipment dam-
age, disconnect electric power to system at main fuse
or circuit breaker box until installation is complete.
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
CAUTION
!
WARNING
!
Question and Answer IconNeed help?

Do you have a question about the White Rodgers 1F80-24 and is the answer not in the manual?

White Rodgers 1F80-24 Specifications

General IconGeneral
Stages1 Heat / 1 Cool
DisplayDigital
Accuracy±1°F
BacklightYes
Temperature Range45°F to 90°F (7° to 32°C)
Voltage24VAC
Battery2 AA Batteries (for backup)

Summary

DESCRIPTION

PRECAUTIONS

CAUTION

Disconnect power before installation to prevent shock or damage.

WARNING

Do not use on circuits exceeding voltage; may cause shock or fire.

SPECIFICATIONS

ELECTRICAL DATA

Details electrical ratings including voltage and current limits for the thermostat.

THERMAL DATA

Specifies temperature ranges for setpoints, operation, and shipping.

APPLICATIONS

Lists compatible and incompatible heating and cooling system types.

INSTALLATION

REMOVE OLD THERMOSTAT

Steps to safely remove the existing thermostat and prepare for the new unit.

ELECTRIC HEAT OR HEAT PUMP SYSTEMS

Guidance on setting the electric heat switch for specific system types.

ATTACH THERMOSTAT BASE TO WALL

Instructions for mounting the thermostat base securely to the wall.

BATTERY LOCATION

Information on installing and replacing the thermostat's AA batteries.

HYDRONIC (HOT WATER OR STEAM) HEATING SYSTEMS

Instructions for setting the thermostat for hydronic heating systems.

CHECK THERMOSTAT OPERATION

Fan Operation

Procedure to test the fan's automatic and manual operation.

Heating System

Steps to verify the heating system responds correctly to thermostat settings.

OPERATION

Cooling System

Procedure to test the cooling system and understand its 5-minute delay feature.

THE THERMOSTAT BASE

Description of the thermostat's physical components and cover removal.

The Thermostat Buttons and Switches

Identification and function of buttons and switches on the thermostat.

The Display

Explanation of the thermostat's display indicators and their meanings.

OPERATING FEATURES

SIMULTANEOUS HEATING/COOLING PROGRAM STORAGE

Allows setting both heating and cooling programs at once.

TEMPERATURE CONTROL MODES

Covers temperature override and hold settings for manual control.

DISPLAY AND SETTING ADJUSTMENTS

Includes °F/°C conversion, clock format, low battery alert, and temp display adjustment.

PROGRAMMING YOUR THERMOSTAT

Entering Your Program

Steps to input custom heating and cooling schedules into the thermostat.

Set Current Time and Day

Procedure to set the thermostat's internal clock and day.

Enter Heating Program

Detailed steps for programming the four heating periods and temperatures.

Enter Cooling Program

Detailed steps for programming the four cooling periods and temperatures.

CHECK YOUR PROGRAMMING

Instructions to review and verify the programmed heating and cooling schedules.