Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installation and all components of the
system shall conform to Class II circuits per the NEC
code.
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
Your new White-Rodgers 5-Day/1-Day/1-Day Digital Thermo-
stat uses the technology of a solid-state microcomputer to
provide precise time/temperature control. This thermostat offers
you the flexibility to design heating and cooling programs that fit
your needs.
Features:
Separate 5-day (weekday), 1-day (Sat) and 1-day (Sun) pro-
gramming with four separate time/temperature periods per day
Simultaneous heat and cool program storage
Preprogrammed temperature control
LCD continuously displays set point, and alternately
displays time and room temperature
Backlit display when any key is pushed
Temperature override until next program period
Manual program override (HOLD temperature)
Temporary HOLD
°F/°C convertibility
Temperature range 45° to 90°F
R, C, W, W2, G, Y and Y2 terminals
Optional C terminal (Dual Power option)
Program storage in case of power loss.
2 “AA” Energizer
®
alkaline batteries included.
SPECIFICATIONS
ELECTRICAL DATA
Electrical Rating:
20 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-4°F to 150°F
APPLICATIONS
For use with:
Heat/cool systems with up to two stages heat, two
stages cool
DO NOT USE WITH:
Millivolt systems
Systems exceeding 30 VAC and 1.5 amps
3-wire zoned hydronic heating systems
1F81-261
Programmable Electronic
Digital Multi-stage Thermostat
INSTALLATION AND
OPERATION INSTRUCTIONS
Printed in U.S.A.
PART NO. 37-6228B
Replaces 37-6228A
0145
WHITE-RODGERS
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
www.white-rodgers.com
PRECAUTIONS
CAUTION
!
This thermostat is intended for use with a low voltage system; do
not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contractor
or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes and
ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
To prevent electrical shock and/or equipment dam-
age, disconnect electric power to system at main fuse
or circuit breaker box until installation is complete.
WARNING
!
Operator: Save these instructions for future use!

Questions and Answers

  • L
    Lindsay GregoryAug 16, 2025
    How to fix a White Rodgers 1F81-261 Thermostat with no heat, cool, or fan?
    • J
      James ParkerAug 16, 2025
      If your White Rodgers Thermostat isn't producing heat, cool air, or fan, here are a few things to check: * First, look for a blown fuse or tripped circuit breaker and replace the fuse or reset the breaker. * Next, ensure the furnace power switch is turned to the ON position. * Finally, make sure the furnace blower compartment door or panel is correctly installed to engage the safety interlock or door switch.
  • R
    rothmelissaAug 19, 2025
    Why is my White Rodgers Thermostat not producing heat?
    • T
      Travis BrewerSep 12, 2025
      If your White Rodgers thermostat isn't producing heat, consider these potential causes: * The pilot light may not be lit. If so, relight it. * The system switch may not be set to 'Heat.' Ensure it is set to 'Heat' and that the setpoint is above room temperature. * There might be a loose connection to the thermostat or system. Verify that the thermostat and system wires are securely attached. * A furnace lock-out condition might exist. If the heat works intermittently, contact the furnace manufacturer or a local service person. * The heating system may require service, or the thermostat may need replacement. If the thermostat doesn't click after being reset, contact your heating and cooling service person or place of purchase for a replacement.
  • L
    Lisa MunozAug 22, 2025
    How to calibrate my White Rodgers 1F81-261 Thermostat if the setting and thermometer disagree?
    • K
      keith73Aug 22, 2025
      If your White Rodgers Thermostat setting and thermometer disagree, you can adjust the thermometer +/- 4 degrees using item 7 of the Configuration Menu.
  • A
    Alicia MorrisonAug 25, 2025
    What to do if my White Rodgers 1F81-261 display is blank and the keypad isn't responding?
    • C
      Casey HernandezAug 26, 2025
      If your White Rodgers Thermostat has a blank display or the keypad is not responding: * Replace the batteries and check the heating/cooling system for proper operation. * Also, try performing a reset operation, as a voltage spike or static discharge may be the cause.
  • T
    Terri CrossAug 28, 2025
    What to do if my White Rodgers 1F81-261 is not cooling?
    • T
      Tara CarterAug 28, 2025
      If your White Rodgers thermostat isn't cooling, here's what to check: * Make sure the system switch is set to 'Cool' and the setpoint is below room temperature. * Verify that all thermostat and system wires are securely attached, as loose connections can cause this issue. * The cooling system may require service, or the thermostat may need replacement. Contact a local service person for assistance.
  • J
    Johnny ClarkAug 31, 2025
    Why does my White Rodgers 1F81-261 not follow the set program?
    • P
      pmillerAug 31, 2025
      If your White Rodgers Thermostat isn't following the programmed settings: * Check the current clock and program settings, paying close attention to the AM or PM designations for each time period, as they may be set incorrectly. * Also, a voltage spike or static discharge could be the cause. Try using the Reset Operation.
  • B
    Brooke ThorntonSep 3, 2025
    How to stop my White Rodgers 1F81-261 Thermostat from constantly running heat, cool, or fan?
    • H
      Heather McdanielSep 3, 2025
      If your White Rodgers Thermostat is constantly running the heat, cool, or fan, here are some things to consider: * The fan switch might be set to 'Fan On.' Check the setting. * There may be a short in the wiring. Try resetting the thermostat. * If the system operates correctly after resetting, replace the thermostat.
  • D
    daniellefoxSep 6, 2025
    Why does my White Rodgers 1F81-261 Thermostat furnace cycle too fast or slow, causing temperature swings?
    • C
      Chelsey JohnsonSep 6, 2025
      The cycling rate of your White Rodgers Thermostat may be influenced by its location and/or the size of the heating system. You can adjust the cycle rate using Item 2 in the Configuration Menu.
  • Y
    ymooreSep 9, 2025
    What causes my White Rodgers 1F81-261 Thermostat to cycle cooling too fast or slow?
    • C
      Collin VillanuevaSep 9, 2025
      The location of the White Rodgers Thermostat and/or the size of the Cooling System may be influencing the cycle rate. Contact a local service person for suggestions.
  • J
    James GarciaSep 12, 2025
    Why does my White Rodgers 1F81-261 Thermostat start heating or cooling early?
    • T
      tgreerSep 12, 2025
      If your White Rodgers Thermostat starts heating or cooling earlier than expected, the EMR (Early Make Relay) function may be activated. Refer to Configuration Menu (Item 4).

Summary

DESCRIPTION

PRECAUTIONS

SPECIFICATIONS

APPLICATIONS

INSTALLATION

REMOVE OLD THERMOSTAT

Steps for removing the existing thermostat.

ELECTRIC HEAT SYSTEMS

Configuration for electric heating systems.

ATTACH THERMOSTAT BASE TO WALL

Instructions for mounting the thermostat base.

BATTERY LOCATION

Information on battery installation and replacement.

HYDRONIC HEATING SYSTEMS

Setting up the thermostat for hot water or steam systems.

CHECK THERMOSTAT OPERATION

Verifying thermostat and system functionality.

FAN OPERATION

Testing the fan switch for ON and AUTO modes.

OPERATION

THERMOSTAT BUTTONS AND SWITCHES

Identifies and describes the function of each button and switch.

DISPLAY

Explains the icons and information shown on the thermostat display.

CONFIGURATION MENU

Guide to accessing and navigating the thermostat's configuration options.

PROGRAMMING YOUR THERMOSTAT

MANUAL OPERATION

How to manually adjust temperature and override programs.

PLANNING YOUR PROGRAM

Guidance for setting up custom heating and cooling schedules.

ENTERING YOUR PROGRAM

Steps to program heating and cooling times and temperatures.

CHECK YOUR PROGRAMMING

How to review the entered heating and cooling programs.

TROUBLESHOOTING

White Rodgers 1F81-261 Specifications

General IconGeneral
Voltage24 VAC
Stages1 Heat/1 Cool
DisplayDigital
CompatibilityGas, Oil, Electric
BacklightYes
Temperature Range45°F to 90°F
Battery2 AA Batteries
Power SourceHardwired
TypeNon-Programmable Thermostat

Related product manuals