DESCRIPTION
Your new White-Rodgers Digital Thermostat uses the technol-
ogy of a solid-state microcomputer to provide precise tempera-
ture control.
Features:
Simultaneous heat and cool setpoint storage
Pre-set temperature control
Backlit display
LCD continuously displays setpoint and room temperature
°F/°C convertibility
Temperature range 45° to 90°F
RC, RH, C, W, Y, G, O and B terminals
Optional C terminal (Dual Power option)
B and O terminals for single stage heat pumps (no auxiliary
heat) or damper operation
Setpoint storage in case of power toss
®
2 "AA" Energizer alkaline batteries included
PRECAUTIONS
This thermostat is intended for use with a low voltage system; do
not use this thermostat with a line voltage system. If in doubt
about whether your wiring is mittivolt, line, or tow voltage, have
it inspected by a qualified heating and air conditioning contractor
or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes and
ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
To prevent electrical shock and/or equipment dam-
age, disconnect electric power to system at main fuse
or circuit breaker box until installation is complete.
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installation and all components of the
system shall conform to Class II circuits per the NEC
code.
SPECIFICATIONS
ELECTRICAL DATA APPLICATIONS
Electrical Rating:
8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-4°F to 150°F
For use with:
Standard heat/cool or heat only systems
Electric heat systems
Gas or oil fired systems
Gas systems with intermittent ignition devices (I.I.D.)
and/or vent dampers
Hydronic (hot water or steam) systems
Single-stage heat pump systems (no auxiliary heat)
Mittivolt systems
DO NOT USE WITH:
Multi-stage systems
Systems exceeding 30 VAC and 1.5 amps
3-wire zoned hydronic heating systems
EMERSON
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com
PART NO. 37-6585A
0515

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the White Rodgers 1F86-344 and is the answer not in the manual?

White Rodgers 1F86-344 Specifications

General IconGeneral
DisplayDigital
Stages1 Heat/1 Cool
Voltage24 VAC
BacklightYes
MountingHorizontal
TypeNon-Programmable
Power SourceBattery
CompatibilitySingle Stage Heating and Cooling

Related product manuals