This thermostat is intended for use with a low voltage NEC
Class II system. Do not use this thermostat with a line voltage
system. If in doubt about whether your wiring is millivolt, line,
or low voltage, have it inspected by a qualied heating and air
conditioning contractor or electrician.
Do not exceed the specication ratings.
All wiring must conform to local and national electrical codes
and ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could
cause the control to malfunction.
Blue 2” Single Stage Thermostat
Installation and Operating Instructions
Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
APPLICATIONS
For use with the following Class II systems:
Single Stage systems
Single-stage heat pump systems with no Aux heat
DO NOT USE WITH:
Systems exceeding 30 VAC and 1.5 amps
3-wire zoned hydronic heating systems
1F86-0244 Thermostat
Model Programming Choices
1F86-0244
Non-Programmable
SPECIFICATIONS
Electrical Rating:
Battery Power ................................................. mV to 30 VAC, 50/60 Hz or DC
Input-Hardwire ................................................ 20 to 30 VAC
Terminal Load ........................................................ 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range ...................................................... 45° to 90°F (7° to 32°C)
Differential (Single Stage) ...................................... Heat 0.6°F; Cool 1.2°F (adjustable)
Differential (Heat Pump) ........................................ Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient ................................................. 32° to +105°F (0° to +41°C)
Operating Humidity ................................................ 90% non-condensing max.
Shipping Temperature Range ................................ -40° to +150°F (-40° to +65°C)
Dimensions Thermostat ......................................... 3-3/4” H x 4-3/4” W x 1-1/2” D
PRECAUTIONS
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
CAUTION
!
Do not use on circuits exceeding specied voltage.
Higher voltage will damage control and could cause
shock or re hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installation and all components of the
system shall conform to Class II (current limited)
circuits per the NEC code. Failure to do so could cause
a re hazard.
WARNING
!
www.white-rodgers.com
PART NO. 37-7010B
Replaces 37-7010A
0921

Questions and Answers:

White Rodgers 1F86-0244 Specifications

General IconGeneral
DisplayDigital
Stages of Heating1
Stages of Cooling1
Stages1 Heat/1 Cool
BacklightYes
Temperature Range40°F to 90°F
Power SourceBattery or Hardwired
CompatibilitySingle Stage Heat/Cool or Heat Only Systems
Voltage24VAC
MountingWall Mounted
TypeNon-Programmable Thermostat

Summary

APPLICATIONS

For use with the following Class II systems

Lists compatible systems, including single stage and heat pump without auxiliary heat.

DO NOT USE WITH

Lists incompatible systems, such as those exceeding 30 VAC or 1.5 amps.

SPECIFICATIONS

PRECAUTIONS

INSTALLATION

REMOVE OLD THERMOSTAT

Step-by-step instructions for safely removing the existing thermostat from the wall.

ATTACH THERMOSTAT BASE TO WALL

Procedure for mounting the new thermostat base securely to the wall.

O/B TERMINAL SWITCH SELECTION

Guidance on setting the O/B switch for heat pump changeover relay operation.

GAS/ELEC SWITCH

Instructions for setting the GAS/ELEC switch based on system type.

BATTERY LOCATION

Details on battery installation, replacement, and low battery indicators.

WIRING DIAGRAMS

THERMOSTAT QUICK REFERENCE

The Thermostat Buttons and Switches

Identifies and describes the function of the thermostat's buttons and switches.

The Display

Explains the icons and information shown on the thermostat's display screen.

INSTALLER/CONFIGURATION MENU

OPERATION

CHECK THERMOSTAT OPERATION

General guidance on verifying system functionality after installation.

Fan Operation

Instructions for testing the fan switch in ON and AUTO modes.

Heating System

Procedure for testing the heating system by adjusting the setpoint.

Cooling System

Procedure for testing the cooling system, including important temperature precautions.

TROUBLESHOOTING

Reset Operation

Procedure for resetting the thermostat after power interruptions or static discharge.

No Heat/No Cool/No Fan common problems

Troubleshooting steps for common issues like no heat, no cool, or no fan operation.

No Heat

Diagnostic steps and corrective actions for when the heating system is not working.

No Cool

Diagnostic steps and corrective actions for when the cooling system is not working.

Heat, Cool or Fan Runs Constantly

Troubleshooting steps for when the system runs continuously.

Furnace Cycles Too Fast or Too Slow

Addresses issues with furnace cycling rates and temperature swing.

Thermostat Setting and Thermometer Disagree

Information on potential discrepancies between thermostat and room temperature.

Blank Display and/or Keypad Not Responding

Troubleshooting for a blank display or unresponsive keypad.