Installation 2
Wiring Connections 2
Thermostat Quick Reference 3
Installer Configuration Menu 4
Operating Your Thermostat 6
Programming 6
Troubleshooting 8
www.white-rodgers.com
80 Series Thermostat with80 Series Thermostat with
80 Series Thermostat with80 Series Thermostat with
80 Series Thermostat with
Automatic Heat/Cool Changeover OptionAutomatic Heat/Cool Changeover Option
Automatic Heat/Cool Changeover OptionAutomatic Heat/Cool Changeover Option
Automatic Heat/Cool Changeover Option
PART NO. 37-6749A
0604
Single Stage or Heat Pump
Installation and Operating Instructions for Model:
APPLICATIONS
Description
Gas or Oil Heat Yes
Electric Furnace Yes
Heat Pump (No Aux. or Emergency Heat) Yes
Heat Pump (with Aux. or Emergency Heat) No
Systems with up to 3 Stages Heat, 2 Stages Cool No
Heat Only Systems Yes
Millivolt Heat Only Systems – Floor or Wall Furnaces Yes
Cool Only Systems Yes
Hydronic (Hot Water) Zone Heat – 2 Wires Yes
Hydronic (Hot Water) Zone Heat – 3 Wires Yes
THERMOSTAT APPLICATION GUIDE
1F86-0471 Thermostat
SPECIFICATIONS
Electrical Rating:
Battery Power . . . . . . . . . . . . . . . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire . . . . . . . . . . . . . . . . . . . . . . . . 20 to 30 VAC
Terminal Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range . . . . . . . . . . . . . . . . . . . . . . . . . . . 45° to 90°F (7° to 32°C)
Differential (Single Stage) . . . . . . . . . . . . . . . . . . . Heat 0.6°F; Cool 1.2°F (adjustable)
Differential (Heat Pump) . . . . . . . . . . . . . . . . . . . . Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient . . . . . . . . . . . . . . . . . . . . . . . . . 32° to +105°F (0° to +41°C)
Operating Humidity . . . . . . . . . . . . . . . . . . . . . . . . 90% non-condensing max.
Shipping Temperature Range . . . . . . . . . . . . . . . . -4° to +150°F (-20° to +65°C)
Dimensions Thermostat . . . . . . . . . . . . . . . . . . . . . 3.4"H x 4.4"W x 1.3"D
To prevent electrical shock and/or equipment dam-
age, disconnect electric power to system at main fuse
or circuit breaker box until installation is complete.
CAUTION
!
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this
product may replace a product that contains mercury.
Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
spilled mercury and place in a sealed container. For proper
disposal of a product containing mercury or a sealed
container of spilled mercury, place it in a suitable shipping
container and send it to:
White-Rodgers
2895 Harrison Street
Batesville, AR 72501
Index Page
Model Programming Choices
1F80-0471
5/2 Day 5/1/1 Day Non-Programmable
1F86-0471 Non-Programmable
Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.

Questions and Answers:

White Rodgers 1F86-0471 Specifications

General IconGeneral
BrandWhite Rodgers
Model1F86-0471
TypeNon-Programmable
Stages1 Heat / 1 Cool
Display TypeDigital
Wi-Fi CapabilityNo
Voltage24 VAC
BacklightYes
Weight0.5 lbs
Power SourceBattery
CompatibilitySingle Stage Heating and Cooling Systems
Temperature Range45°F to 90°F
Battery2 AA batteries

Summary

CAUTION

INSTALLATION

THERMOSTAT QUICK REFERENCE

INSTALLER/CONFIGURATION MENU

Reversing Valve Output

Configure the O/B terminal for heat pump changeover relay.

Program Options

Select programming mode: 5/2 Day, 5/1/1 Day, or Non-programmable.

Cool Savings

Enable or adjust automatic setpoint adjustments for energy saving.

Energy Management Recovery

Enable early start for heating/cooling to meet programmed setpoints.

Cycle Rate Selection

Adjust heating/cooling cycle rate for system efficiency.

Compressor Lockout

Set a delay to prevent compressor short cycling.

System Mode Configuration

Set system operation modes like Auto changeover or Heat/Cool only.

Filter Replacement Run Time

Set reminder for filter change based on blower operation hours.

OPERATING YOUR THERMOSTAT

PROGRAMMING (For Programmable Model Only)

TROUBLESHOOTING

Reset Operation

Procedure to reset thermostat to factory settings.

No Heat/No Cool/No Fan (common problems)

Diagnose and correct common issues with heating, cooling, or fan operation.

No Heat

Troubleshoot and identify causes for lack of heating.

Related product manuals