CAUTION
!
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
This thermostat is intended for use with a low voltage system;
do not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contrac-
tor or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes
and ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
Your new White-Rodgers Digital Thermostat uses the
technology of a solid-state microcomputer to provide precise
temperature control.
Features:
• Simultaneousheatandcoolsetpointstorage
• Setpointstorageincaseofpowerloss
• Pre-settemperaturecontrol
• LCDcontinuouslydisplayssetpointandroomtemperature
• ContinuousBacklitdisplayoption
• °F/°Cconvertibility
• Temperaturerange45°to90°F
• R,C,Y,W2,G,O/B,E,andLterminalsforsingleortwo-
transformer systems
• Optional"AA"batteriestoprovidecontinuoustemperature
displayduringlossofACpower
SPECIFICATIONS
ELECTRICAL DATA
Electrical Rating:
20to30VAC50/60Hz.orD.C.
0.05to1.0Amps(Loadperterminal)
1.5 Amps Maximum Total Load(Allterminalscombined)
THERMAL DATA
Setpoint Temperature Range:
45°Fto90°F(7°Cto32°C)
Operating Ambient Temperature Range:
32°Fto105°F
Operating Humidity Range:
0to90%RH(non-condensing)
Shipping Temperature Range:
-4°Fto149°F
APPLICATIONS
Forusewith:
• Standardheatpumpsystemswithelectric,gasoroilAux
heatwith24VACHOTandCOMMONavailable
• Single-stageheatpumpsystemswithnoAuxheatwith
24VACHOTandCOMMONavailable
DO NOT USE WITH:
• Millivoltsystems
• Systemsexceeding30VACand1.5amps
• 3-wirezonedhydronicheatingsystems
1F89-211
Non-programmableElectronicDigital
HeatPumpThermostat
INSTALLATION AND
OPERATION INSTRUCTIONS
PRECAUTIONS
WARNING
!
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installation and all components of the
system shall conform to Class II (current limited)
circuits per the NEC code. Failure to do so could cause
a fire hazard.
Operator: Save these instructions for future use!
www.white-rodgers.com
www.emersonclimate.com
PART NO. 37-6233F
Replaces37-6233E
1338

Questions and Answers

  • W
    William ZunigaSep 10, 2025
    How to fix a White Rodgers 1F89-211 Thermostat that cycles too fast or slow with heat?
    • G
      Gregory MontgomerySep 10, 2025
      The location of the thermostat or the size of the heating system can influence the cycle rate. Item 2 in the Configuration Menu controls the cycle rate. If an acceptable cycle rate is not achieved using the FA (Fast) or SL (Slow) adjustment contact a local service person for additional suggestions.
  • T
    Timothy ShepardAug 22, 2025
    How to calibrate my White Rodgers Thermostat if the setting and thermometer disagree?
    • L
      Laura ParkerAug 22, 2025
      If the thermostat setting and thermometer reading disagree on your White Rodgers Thermostat, the thermometer setting may require adjustment. You can adjust the thermometer +/- 4 degrees using item 7 of the Configuration Menu.
  • M
    michaelwilliamsAug 25, 2025
    Why is my White Rodgers 1F89-211 Thermostat not cooling?
    • R
      ryansmithAug 25, 2025
      If your White Rodgers Thermostat is not cooling, make sure the System Switch is set to Cool and lower the setpoint below room temperature. Check that the thermostat and system wires are securely attached. If the issue persists, the cooling system might require service.
  • S
    Stephanie TaylorAug 26, 2025
    Why is my White Rodgers 1F89-211 Thermostat not blowing heat?
    • P
      Paula BoyleAug 26, 2025
      The system switch might not be set to 'Heat,' there could be a loose connection to the thermostat or system, or the heating system may require service, or the thermostat may need replacement. Set the system switch to 'Heat' and raise the setpoint above room temperature. Also, verify that the thermostat and system wires are securely attached.
  • M
    Melinda CruzAug 27, 2025
    Why is my White Rodgers Thermostat not blowing cool air?
    • S
      scott86Aug 27, 2025
      The system switch may not be set to 'Cool', there may be a loose connection to the thermostat or system, or the cooling system might require service or the thermostat might need replacing. Set the system switch to 'Cool' and lower the setpoint below room temperature. Verify that the thermostat and system wires are securely attached.
  • S
    Stephanie GonzalezAug 29, 2025
    How to fix a White Rodgers 1F89-211 that is not cooling?
    • M
      Michelle PhelpsAug 29, 2025
      If your White Rodgers Thermostat isn't cooling, ensure the System Switch is set to 'Cool' and the setpoint is lower than the room temperature. Also, verify that all thermostat and system wires are securely attached. If the problem continues, the cooling system may require service or the thermostat may need replacing, so contact a qualified service person or the place of purchase.
  • S
    susan27Sep 18, 2025
    Why is my White Rodgers 1F89-211 Thermostat not blowing heat, cool, or fan?
    • D
      Dylan DavidSep 18, 2025
      The issue might stem from a blown fuse or tripped circuit breaker, a furnace power switch being set to OFF, or the furnace blower compartment door/panel not being properly installed. To resolve this, replace the fuse or reset the breaker, ensure the furnace power switch is ON, and correctly replace the door panel to engage the safety interlock or door switch.
  • S
    smithlindsaySep 12, 2025
    What to do if my White Rodgers 1F89-211 display is blank or the keypad isn't responding?
    • S
      Sheryl NormanSep 12, 2025
      This could be due to a loss of power or a voltage spike/static discharge. Check the heat/cool system for power. If a voltage spike or static discharge occurred, use the Reset Operation.
  • H
    hperkinsSep 8, 2025
    Why does my White Rodgers 1F89-211 setting and thermometer disagree?
    • J
      jhillSep 8, 2025
      The thermostat thermometer setting may require adjustment. You can adjust the thermometer +/- 4 degrees as listed in item 7 of the Configuration Menu. No other adjustment is possible.
  • C
    Christopher CombsSep 5, 2025
    How to adjust thermometer on White Rodgers 1F89-211 Thermostat?
    • R
      Robert ThomasSep 5, 2025
      If your White Rodgers Thermostat setting and thermometer disagree, you can adjust the thermometer +/- 4 degrees in item 7 of the Configuration Menu.

Summary

Precautions

Specifications

INSTALLATION

REMOVE OLD THERMOSTAT

Step-by-step instructions for removing the existing thermostat.

ATTACH THERMOSTAT BASE TO WALL

Procedures for mounting the new thermostat base securely to the wall.

WIRING DIAGRAMS

CHECK THERMOSTAT OPERATION

Heating System

Procedure to test heating system operation and auxiliary heat.

Emergency System

How to test the emergency heat function bypassing the heat pump.

Cooling System

Procedure to test cooling system operation and compressor safety.

CONFIGURATION MENU

Select Compressor Lockout (LOC OFF or ON)

Activates a 5-minute delay before compressor restart after power loss.

SETTING THE THERMOSTAT

TROUBLESHOOTING

Reset Operation

Procedure to reset the thermostat after power interruption or erratic operation.

White Rodgers 1F89-211 Specifications