22 WIKA operating instructions, model CPG1500
EN
14161966.06 03/2024 EN/DE
5. Commissioning, operation
CAUTION!
Damage to the instrument through improper use
The area of the display can easily be damaged.
▶
Avoid any contact with hard and pointed objects, or any excessive
pressures.
5.1 Mechanical mounting
Only mount the CPG1500 if it is in perfect condition with respect to safety.
Prior to commissioning, the CPG1500 must be subjected to a visual inspection.
To avoid possible damage to the CPG1500 or to test equipment, note the following with
mechanical mounting:
Requirements for mounting point:
▶
Sealing faces are clean and undamaged
▶
Maximum pollution degree of the environment (2)
▶
For information on tapped holes, see technical information IN 00.14 at
www.wika.com.
▶
Permissible ambient and medium temperatures remain within the performance limits.
→ For performance limits, see chapter 10 “Specifications”
5.1.1 Sealing the process connection
▶
When screwing the threads of the CPG1500 to an adapter or a pressure connection,
it is necessary to use an additional sealant between the threads, e.g. PTFE tape.
▶
With an NPT connection, the sealing must be made directly on the thread with PTFE
tape and not via the threaded fitting at the CPG1500.
For sealing the process connections with
parallel threads, flat gaskets, lens-type
sealing rings or WIKA profile sealings must
be used at the sealing face
1
.
For sealing process connections with tapered
threads, the sealing is made in the threads
using additional sealing material, e.g. PTFE
tape (EN 837-2).
Parallel threads
per EN 837
1
Tapered threads
NPT, R and PT