30 WIKA operating instructions pressure transmitter, model IS-3
MM/YYYY country code based on 14095850.02 12/2014 EN/CN
EN
3.12 Weight
approx. 0.2 kg
Field case approx. 0.35 kg
Measuring ranges > 1,000 bar approx. 0.3 kg (approx. 0.45 kg with eld case)
3.13 CE conformity
Pressure equipment directive
97/23/EC
EMC directive
2004/108/EC, EN 61326 emission (group 1, class B) and interference immunity (industrial application)
During interference respect an increased measuring deviation up to 1 %.
ATEX directive
94/9/EC
3.14 Approvals
IECEx, international certication for the Ex area
SIL2, functional safety
GL, ships, shipbuilding (e.g. oshore), Germany
For further specications see WIKA data sheet PE 81.58 and the order documentation.
3.Specications

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WIKA IS-3 and is the answer not in the manual?

WIKA IS-3 Specifications

General IconGeneral
Output Signal4 ... 20 mA, 2-wire
Power Supply10 ... 30 VDC
MaterialStainless steel
Accuracy≤ ±0.5 % of span
Temperature Range-20 ... +85 °C
Ingress ProtectionIP65
Long-term stability±0.2 % FS per year
Process ConnectionG 1/4, G 1/2, 1/4" NPT, 1/2" NPT
Electrical ConnectionM12 x 1