WIKA operating instructions models PGS10, PGS11 and PGS21
7
2.4 Labelling / safety marks
Product label
Explanation of symbols
CE, Communauté Européenne
Instruments bearing this mark comply with the relevant
European directives.
3. Specications
2. Safety / 3. Specications
Prange ... scale range
P
switch ... switch point
Model
Pin assignment
Models PGS10, PGS11 and PGS21
Pressure limitation
- Steady 3/4 x full scale value
- Fluctuating 2/3 x full scale value
- Short time Full scale value
Temperature eect When the temperature of the measuring system
deviates from the reference temperature (+20 °C):
max. ±0.4 %/10 K of the span
Ingress protection
- Enclosing case per EN 60529 / IEC 529
Model PGS10 and PGS11: IP 43
Model PGS21: IP 65
Operating temperature
- Ambient -20 ... +60 °C
- Medium Maximum +60 °C
For further specications see data sheet PV 20.01, PV 21.01, PV 21.02 and
the order documentation.
11581752.01 07/2010 GB/D/F/E
GB