Pressure gauges with inductive contact model 831, for hazardous areas28
14320154.01 06/2019 EN/DE
EN
Models PGS43.100, PGS43.160
Pressure limitation
Steady Full scale value
Fluctuating 0.9 x full scale value
Short time 5 x full scale value, however max. 40 bar
Temperatureeect When the temperature of the measuring system deviates
from the reference temperature (+20 °C): max. ±0.8 %/10 K
of full scale value
Wetted materials
Process connection with lower
measuring ange
Stainless steel 316L
Pressure element ≤ 0.25 bar: Stainless steel 316L
> 0.25 bar: NiCr alloy (Inconel)
Sealing FPM/FKM
Non-wetted materials
Case, movement, bayonet ring Stainless steel
Dial Aluminium, white, black lettering
Instrument pointer Aluminium, black
Set pointer Aluminium, red
Window Laminated safety glass
Ingress protection per IEC/EN 60529 IP54
For further specications see data sheet PV 24.03
9. Specifications
Model 232.35.063
Pressure limitation
Steady 3/4 x full scale value
Fluctuating 2/3 x full scale value
Short time Full scale value
Temperatureeect When the temperature of the measuring system deviates
from the reference temperature (+20 °C): max. ±0.4 %/10 K
of full scale value
Wetted materials
Process connection, pressure element Stainless steel 316L
Non-wetted materials
Case, movement, bayonet ring Stainless steel
Dial Aluminium, white, black lettering
Pointer Aluminium, black
Window Laminated safety glass
Ingress protection per IEC/EN 60529 IP54
For further specications see data sheet PM 02.11