• R-290 (propane) is ammable and heavier than
air. It accumulates rst in low areas but can be
circulated by fans.
• If propane gas is present or even suspected, do
not allow untrained personnel to attempt to nd
the cause.
• The propane gas used in the unit has no odor.
• The lack of smell does not indicate a lack of
escaped gas.
• If a leak is detected, immediately evacuate all
persons from the room, ventilate the room and
contact the local re department to advise them
that a propane leak has occurred.
• Do not let any persons back into the room until
the qualied service technician has arrived and
that technician advises that it is safe to return to
the room.
• No open ames, cigarettes or other possible
sources of ignition should be used inside or in the
vicinity of the units.
• Component parts are designed for propane and
non-incentive and non-sparking. Component
parts shall only be replaced with identical repair
parts.