Top Mounted Cabinets (WBC/WBCF50)
The condensing unit and refrigeration equipment can be accessed from above or in some cases behind.
Remove the screws in the top and bottom edge of the unit cover and pull the unit cover away from the
cabinet and retaining clips.
Bottom Mounted Units (WBC/WBCF10-40)
Pull the unit cover away from the cabinet and retaining clips.
Once cleaning or any maintenance is completed replace the unit covers and plug the cabinet in to
restart operation.
EVAPORATOR/DRAINLINE
Should be inspected periodically to ensure the drain hole is not blocked.
REPLACING THE GASKET
Damaged gaskets are easily replaced. To fit a new gasket - simply pull out the old gasket and push the
new gasket into the channel (gasket retainer) at the centre and work along the gasket pushing it into the
channel, continue in the same way on the other three sides, pushing the corners in last.