Safety en
Installation and operating instructions Wilo-EMU FA + FK 17.1, FK 202, FK 34, FK 42 7
Personal protective equipment: Wear a safety helmet
Personal protective equipment: Wear foot protection
Personal protective equipment: Wear hand protection
Personal protective equipment: Wear mouth protection
Personal protective equipment: Wear safety goggles
Autonomous work prohibited! A second person must be present.
Useful information
2.2 Personnel qualifications
Personnel must:
Be instructed in the locally applicable accident prevention regulations.
Have read and understood the installation and operating instructions.
Personnel must have the following qualifications:
Electrical work: Electrical work must be carried out by a qualified electrician (in accord-
ance with EN50110-1).
Installation-/dismantling: The technician must be trained in the use of the necessary
tools and mounting materials for the relevant construction site.
Maintenance tasks: The technician must be familiar with the use of operating fluids and
their disposal. In addition, the technician must have basic knowledge of mechanical en-
gineering.
Definition of “qualified electrician”
A qualified electrician is a person with appropriate technical education, knowledge and
experience who can identify and prevent electrical hazards.
2.3 Electrical work
A qualified electrician must carry out the electrical work.
When connecting to the mains, comply with the locally applicable laws and regulations
of the local energy supply company.
Before commencing work, disconnect the device from the mains and secure it against
being switched on again without authorisation.
Personnel is trained on the execution of the electrical connection and the options for
switching off the device.
Comply with the technical specifications contained in these installation and operating
instructions and on the rating plate.
Earth the device.
Observe the manufacturer’s specifications when connecting to electrical switching sys-
tems.
Comply with the specifications on electro-magnetic compatibility when connecting
electronic start-up controllers (e.g. soft starter or frequency converter). If required, take
into account special measures (e.g. shielded cables, filters etc.).
Replace defective power supply cables immediately. Contact customer service.
2.4 Monitoring devices
The following monitoring equipment must be provided on-site:
Circuit breaker
The size of the circuit breakers conforms to the rated current of the pump. The switch-
ing characteristics should comply with group B or C. Observe local regulations.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wilo Wilo-EMU FA + FK 202 and is the answer not in the manual?

Wilo Wilo-EMU FA + FK 202 Specifications

General IconGeneral
BrandWilo
ModelWilo-EMU FA + FK 202
CategoryWater Pump
LanguageEnglish

Related product manuals