MAINTENANCE
86221970 17” SCRUBBER 01/03/07
4
-
7
SERVICE SCHEDULE
MAINTENANCE DAILY WEEKLY MONTHLY ANNUALLY
Check battery acid level *
Check vac hose connections *
Clean the squeegee blades *
Inspect brush or pad for debris:
wire string, wear
*
Inspect float ball screen *
Drain & rinse tanks *
Raise squeegee assembly *
Raise scrub deck assembly *
Charge the batteries. *
Remove the pad driver/brush *
Check the brush/pad for damage
and/or wear
*
Clean squeegee blades *
Clean recovery tank shut off &
screen
*
Check battery cells w/ hydrometer *
Check solution strainer *
Check pivot points and casters for
proper lubrication
*
Inspect tank and hoses *
Clean tops of batteries *
Check battery cable clamps *
Use a vacuum to remove lint from
the motor windings
*
Grease casters *
Inspect all motors for carbon
motor brush wear
*
End of work
period
before
storing
Before
starting
the work
period