Maintenance 28
9 Descaling
The technician can carry out descaling using a descaling adapter (located behind the left-hand door and
a silicone hose). A descaling tank (5l capacity) is needed and should be placed as close as possible to the
machine.
Dosage is identical to the WMF 1500S (2 bottles of descaler to 3 of water).
Instructions:
Please also order a silicon hose for descaling 00.0048.0064 (8x2 1.5 meters).
The descaling is executed using a display-guided descaling routine.
Technician descaling:
The technician can carry out a reduced descaling at a higher descaling temperature using service routines after
entering the master PIN.
Brief description of the display-guided descaling routine:
Start the descaling routine
Pressure reduction
Descaling
3 rinsings