86
User Manual WMF5000 S
Appendix: Technical data
Ambient temperature +5°C to +35°C
(empty the water system in case of frost).
Maximum humidity 80 % relative humidity without condensation.
Do not use device outdoors.
Installation surface/water spray The device must be placed and leveled on
ahorizontal, sturdy, water-resistant, and
heatproof base.
The device must not be cleaned using awater
jet. The device must be installed where it is
protected against water spray. The device must
not be located on asurface that is sprayed or
cleaned with awater hose, steam jets, steam
cleaner, or similar devices.
Installation clearances
For operating, service and safety reasons the
machine should be installed with aclearance of
not less than 50mm at the back and sides from
the building or non-WMFcomponents.
A minimum working space of 800mm in front
the coffee machine and overhead clearance of
at least 200mm above the product hoppers are
recommended. Aclear height of 1,100mm from
the top of the installation surface should be
ensured. The height of the installation surface
above the floor is at least 850mm. If the coffee
machine connections are to be run downwards
through the counter, please make space for the
lines, which can reduce the usable space below
the coffee machine.
Installation dimensions of the
water filter
See the User Manual for the water filter.