EasyManuals Logo

WMF espresso User Manual

WMF espresso
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
Service 19
2.13 Admixture calibration for proportional valve
Given the heavy temperature fluctuations at the start of brewing cycle, the initial opening path of the proportional valve can be adjusted via the mixing calibra-
tion (=cold water mixing amount) as follows
Start beverage
First value displayed = target temperature configured in the recipe
Observe the max. and min temperature
With larger deviations, between the target and max/min
configure this difference temperature
Service > Service routines > Mixing calibration
lower.
Repeat the procedure until the temperature
has leveled out to +/- 2 °C.
Example for determining the temperature difference:
First value displayed
= target temperature configured in the recipe = 92°C
Max. temperature during beverage serving = 98°C
Temperature difference +6°C
Mixing calibration setting: -6°C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WMF espresso and is the answer not in the manual?

WMF espresso Specifications

General IconGeneral
Product TypeEspresso Machine
BrandWMF
Pressure15 bar
MaterialStainless Steel
FeaturesAutomatic milk frother, removable water tank