Forbidden to use the air compressor to clean the machine.
B. THE ELECTRICAL PART
1. GENERAL SPECIFICATIONS
General power: 380 VAC + 10% -- 15% 50Hz 3-phases
Spindle motor: 380 VAC 50 Hz 2.2 KW
Motor of coolant system: 380 VAC 50Hz 40W
Motor of tool post: 380 VAC 50Hz 60W
Work light: 24 VAC 40W
2. CONDITIONS TO USE THE ELECTRIC PARTS.
Condition of power alternating current (AC) 380AVC + 10% -- 15%
50Hz 3-phases
Aggregate capacity: 3 KW
Condition of circumstance: A. without caustic chemical gas. B.
temperature from 0-40 centigrade. C. relative humidity (RH) will not
be more than 80%. D. height above sea level will not be higher than
2000m
3. CHECK BEFORE CONNECTION WITH POWER
To ensure safety of the personnel and the equipment, the careful
checking on all the electric parts is needed before connection with the
power.
To check whether it is right or not for the connection of all the electric
parts.
To check whether all the fastening pieces get loose or not.