Wolf CGB-2 Series - Setting the DHW Flow Limiter

Wolf CGB-2 Series
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3064810_201804 65
33.Settingtheowlimiter
Thecombi boiler istted with anadjustable ow
limiter(DHWdraw-offrate).
Theowlimiterisshippedwithaowratesetatthefactory
to 8 l/min.
Theowratecanbechangedviathegreenrotaryselector
ontheowlimiter.
Theowlimitercanbeadjustedbetween5and13l/min.
Procedure:
• Manually pull out the green rotary selector forwards.
• IncreaseowrateÞ
rotate counter clockwise in + direction.
• ReduceowrateÞ
rotate clockwise in - direction.
Checktheselectedowrateonthedisplayofthe
AM display module or the BM-2 programming unit.
• Manually push in the green rotary selector to lock it.
Recommendeddraw-offrate
Appliancetype ΔT=40K ΔT=50K
CGB-2K-20 8.6 l/min 6.8 l/min
CGB-2K-24 10 l/min 8 l/min
Fig: Flow rate limiter
Seite 26
Durchflussmengenregler