Summary

General Information

Safety Instructions

If you smell gas

Steps for gas detection, safety, and emergency contact.

If you smell flue gas

Procedures for flue gas issues, including shutdown and technician contact.

Changing a fuse

Procedure for safe fuse replacement, emphasizing power isolation.

Frost protection

Boiler frost protection and draining procedures.

Balanced flue system risks

Ice formation risk on flue pipe and safety measures.

Installation and Maintenance Information

Installation and modifications

Authorized installation, modifications, and ventilation restrictions.

Corrosion protection

Preventing boiler corrosion via water quality and chemical avoidance.

Care and maintenance

Cleaning instructions and requirements for regular system maintenance and annual servicing.

Water Connections and Gas Supply

Pre-commissioning checks

Critical pre-commissioning checks, system filling, and contamination prevention.

Filling the heating system

Procedure for filling the system, checking pressure, and disconnecting connections.

Siphon fitting and filling

Instructions for fitting and filling the siphon with model-specific diagrams.

Shut-off equipment operation

Operation of shut-off valves and gas shut-off valve.

Water level check

Regular checks of water level and recommended system pressure.

Control Unit Operation

Illuminated ring status indicator

Meaning of different colours and patterns of the illuminated ring.

Operating modes and settings

Details on summer/winter modes, test modes, and temperature selectors.

Energy-Efficient Operation

Heating mode efficiency

Using condensing technology and heating pumps efficiently.

Lowest energy level operation

Operating at low return temperatures and using control units for cost savings.

Preventing home overheating

Accurate room temperature setting and thermostat use for energy saving.

Air circulation for efficiency

Ensuring proper airflow for radiators and sensors to maximize effectiveness.

Reducing night heat loss

Tips for minimizing heat loss at night via windows and insulation.

Sensible ventilation for efficiency

Effective ventilation methods to minimize heat loss and maintain comfort.

Radiator venting

Regular radiator venting for optimal performance and response.

DHW circulation pump use

Using time switches for DHW circulation pumps to match demand and save energy.

Optimum DHW temperature

Setting DHW and cylinder temperature to required levels to save energy.

Continuous DHW handling

Reducing hot water consumption by showering and fixing leaks.

Faults and fault codes

Reading fault codes, restarting the boiler, and contacting technicians.