EasyManua.ls Logo

Wolf CGS-20/160 User Manual

Wolf CGS-20/160
56 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Art.-Nr. 3044826_201403 Änderungen vorbehalten
Wolf GmbH · Postfach 1380 · 84048 Mainburg · Tel. 08751/74-0 · Fax 08751/741600 · Internet: www.wolf-heiztechnik.de
DE
ES
GB
Wartungsanleitung
Gasbrennwertgeräte
CGB-(K)-11/20/24, CGS-20/160, CGS-24/200,
CGW-11/100 CGW-20/120, CGW-24/140,
CGI-20/120, TGC-20/24, TGS-20/160
Seite 2 -18
Manual de mantenimiento
Caldera de condensacion a gas
CGB-(K)-11/20/24, CGS-20/160, CGS-24/200,
CGW-11/100 CGW-20/120, CGW-24/140,
CGI-20/120, TGC-20/24, TGS-20/160
Página 19 - 36
Service Manual
Gas condensing boilers
CGB-(K)-11/20/24, CGS-20/160, CGS-24/200,
CGW-11/100 CGW-20/120, CGW-24/140,
CGI-20/120, TGC-20/24, TGS-20/160
Page 37 - 54
Question and Answer IconNeed help?

Do you have a question about the Wolf CGS-20/160 and is the answer not in the manual?

Wolf CGS-20/160 Specifications

General IconGeneral
Modulation range20-100%
Nominal heat output 80/60 °C20 kW
Energy efficiency classA
Heating capacity20 kW
Max working pressure3 bar
Fuel typeNatural gas
TypeCondensing gas boiler

Summary

Service Manual

Safety Instructions

Instructions and symbols for personal safety and operational reliability during maintenance.

General Notes

Important notes regarding qualified technicians, original parts, and maintenance contracts.

Assembly Procedures

Checking the Siphon

Instructions for cleaning and refilling the siphon, and checking its fit.

Check Sacrificial Anode (CGS only)

Procedure for checking and replacing the sacrificial anode on CGS models.

Remove Access Trap Cover (CGW only)

Steps to disassemble, remove, and reassemble the access trap cover on CGW models.

Completing Adjustments and Tests

Test Run

Steps for performing a test run, including resetting MCBs and setting the selector.

Ventilation Test

Procedure for conducting a ventilation test and checking the LAF for soundness.

Flue Gas Test

Instructions for re-adjusting the CO₂ content based on flue gas test results.

Gas-Air Mixture Adjustment

CO₂ Adjustment at Upper Load

Procedure for adjusting CO₂ content at upper load using emissions test mode.

CO₂ Adjustment at Lower Load

Procedure for adjusting CO₂ content at lower load (soft start) using the zero point screw.

Checking the CO₂ Adjustment

Steps to check CO₂ adjustment with the boiler closed and observe CO emissions.

Completing the Adjustments

Final steps to complete adjustments, including switching off and checking for leaks.

Control Accessories Check

Maintenance Report Overview

Related product manuals