Induction Range (IR) Series
Induction Range (IR) Series
Component Removal
3-6
#827176 - Revision A.1 - December, 2016
Halogen Bulb Removal
There are two halogen lamps in the oven cavity. There
is a pressed on glass lens that covers the bulb.
To remove the halogen bulb, first remove the rack guide
on the side of the oven where the halogen bulb needs
to be replaced, then (See Figure 3-10):
Use a flat bladed screw driver to remove the glass1
lens.
Use a clean, dry, oil free cloth to remove and install2
the new halogen bulb.
Convection Baffle Removal
The convection baffle covers the convection fans and
elements. It is attached to the back wall with screws.
To remove the convection baffle, first remove the rack
guides, then (See Figure 3-11):
Extract the screws above and below the convection1
baffle.
Remove the convection baffle from the oven cavity.2
Convection Element Removal
The convection element surrounds the convection fan
and is held in place with three screws.
To remove the convection element, first remove the
convection baffle, then (See Figure 3-12):
Extract the two top screws and one bottom screw1
from the convection element supports.
Tilt the bottom of the element up to pull the spade2
terminals with the wires attach through the back
wall.
Disconnect the wires from the convection element3
spade terminals.
Remove the convection element.4
Figure 3-11. Convection Baffle Removal
Figure 3-12. Convection Element Removal
Figure 3-10. Convection Baffle Removal