Component Removal
Induction Range (IR) Series
Induction Range (IR) Series
3-7
#827176 - Revision A.1 - December, 2016
Convection Fan Removal.
The convection fans are held in place with screws to
the back wall of the oven. The left fan has five screws
and the right fan has six screws so that the fans can
not be reversed.
To remove the convection fan, first remove the convec-
tion element, then (See Figure 3-13):
Extract the screws from the fan shroud.1
Remove the fan from the back wall.2
Disconnect the electrical wires from the fan.3
Remove the fan from the oven.4
Temperature Sensor Removal
The temperature sensor is attached to the back wall of
the oven.
To remove the temperature sensor, first remove the
oven racks, then (See Figure 3-14):
Extract the screws from the temperature sensor.1
Pull the temperature sensor into the oven cavity.2
Disconnect the wire harness.3
Remove the temperature sensor.4
Smoke Catalyst Removal
The smoke catalyst is located in the top of the oven
cavity.
To remove the smoke catalyst, first remove the oven
racks, then (See Figure 3-15):
Extract the screws from the smoke catalyst.1
Remove the smoke catalyst.2
Figure 3-13. Convection Fan Removal
Figure 3-14. Temperature Sensor Removal
Figure 3-15. Smoke Catalyst Removal