62
W OLF C OOKTOP V ENTILATION
PLANNING
INFORMATION
Space Requirements
Installation of the chimney wall or
island hood should be 24" (610) to
30" (762) from the bottom of the
hood to the cooking surface.
Refer to the installation instructions
provided each Wolf ventilation
product for detailed specifications.
These instructions can also be found
on the Wolf website.
Electrical Requirements
Wolf chimney wall and island hoods
require a separate, grounded 120V,
60 Hz power supply. The service
should have its own 15 amp circuit
breaker. Placement of the electrical
supply is not critical, as long as you
provide a minimum of 6' (1.8 m) of
120V AC power cable. Locate electri-
cal as shown in the illustrations.
IMPORTANT NOTE: A ground fault
circuit interrupter (GFCI) is not
recommended and may cause inter-
ruption of operation.
You must follow all National Electrical
Code regulations. In addition, be
aware of local codes and ordinances
when installing your service.