81
P RO S ERIES V ENTILATION R ECOMMENDATIONS
Wall Hoods
24" (610) Deep R/DF304 R/RT/DF364 R/RT/DF366 R/RT488 R/RT/DF486 R/RT/DF484 R/RT482 R/DF606 R/DF604
W302418 600
W362418 600 900 900
W422418 900 900
W482418 1200 1200 900 900
W542418 1200 1200 900 900
W602418 1500 1200
W662418 1500 1200
Wall Hoods
27" (686) Deep R/DF304 R/RT/DF364 R/RT/DF366 R/RT488 R/RT/DF486 R/RT/DF484 R/RT482 R/DF606 R/DF604
W302718 600
W362718 600 900 900
W422718 900 900
W482718 1200 1200 900 900
W542718 1200 1200 900 900
W602718 1500 1200
W662718 1500 1200
Wall Hoods
22" (558) Deep R/DF304 R/RT/DF364 R/RT/DF366 R/RT488 R/RT/DF486 R/RT/DF484 R/RT482 R/DF606 R/DF604
W302210I 600
W362210I 600 900 900
W362210 600 900 900
W422210 900 900
W482210 900 900
NOTE: Do not use a 22" (558) deep wall hood with Wolf Dual Fuel Range, Gas Range and Rangetop models with a charbroiler or griddle.
Island Hoods R/DF304 R/RT/DF364 R/RT/DF366 R/RT488 R/RT/DF486 R/RT/DF484 R/RT482 R/DF606 R/DF604
I363418 600
I423418 600 900 900
I543418 1200 1200 900 900
I663418 1500 1200
Hood Liners R/DF304 R/RT/DF364 R/RT/DF366 R/RT488 R/RT/DF486 R/RT/DF484 R/RT482 R/DF606 R/DF604
L282212I 600
L342212 900 900
L402212 900 900
L462212 1200 1200 900 900
L522212 1200 1200 900 900
L582212 1500 1200
NOTE: CFM recommendations are based on total Btu/hr output. Wolf recommends 1 CFM per 100 Btu/hr (.03 kWh). Additional CFM may
be required for charbroilers, griddles and long duct runs.
CFM RECOMMENDATIONS