BASIC WIRING
115 VAC comes in through the junction box, then plugs into the electrical box. It is wired to the power board with a three-wire harness.
For internal blowers, 115 VAC is sent from the power board to the blower.
For inline and remote blowers, 115 VAC is sent from the power board to the terminal block where the inline or remote blower is
connected.
The blower speed is controlled by a triac on the power board assembly.
Voltage goes through the ribbon cable harness from the power board and connects to the ribbon cable from the hood body to provide
power to the touch control. A signal back to the power board returns through the same ribbon cables.
115 VAC is provided to the light transformer on the primary side of the transformer. The transformer converts the 115 VAC to 12 VDC, and
provides power to the LED assemblies through a two-wire harness. The hood body has a two-wire harness from the LED assemblies that
connects to the harness. The orange wires are 120 VAC to the primary side of the transformer. The harness in the wire sheath is 12 VDC
to the hood lights. The connector with gray, black, and white wires is 12 VDC to the touch control.
Wolf V-Series Cooktop Hoods Service Manual
Wiring Diagrams
WIRING DIAGRAMS
service.subzero.com
825309 REV. B
14