EasyManuals Logo

Worcester 24CDi Installation And Servicing Instructions

Worcester 24CDi
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
11
Fig. 10. Functional flow diagram.
Mains
indicator
On/Off
switch
ST8
(L
S)
ST8
(LR)
ST8
(N
S)
ST1
Centre
Pin
ST15
Pin L
REL 1 REL 3
Pump
Fan
ST1
Centre
Pin
ST15
Pin L
ST1
Pin L
REL 1
REL 3
REL 4
2 SPEED FAN
Pump
Fan
ST12 Pin N
Optional link
Room
thermostat
Transformer
Fuse F2
(1.25A Slow)
Fuse F1
(2A Slow)
N
N
ST12 Pin L
LIVE
IN
green
Electronics
Electronics
Electronics
Electronics
Electronics
InputsOutputs
Spark Indicators
Settings
Regulator valve
CH
demand
indicator
Red
Spark
electrodes
DHW
demand
indicator
Red
Flame
detect
indicator
Red
Main valve
Main valve
Flow switch
CH sensor
DHW sensor
Air pressure switch
Flame sense
Overheat cut-off
24V programmer
Reset button
Gas valve mode switch
CH pressure adjust pot
CH Control knob
DHW control knob
Convert AC to low
voltage electronics
Electronics/
microprocessor
(Safety Low Voltage)
24CDi
28CDi 35CDi
II

Other manuals for Worcester 24CDi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester 24CDi and is the answer not in the manual?

Worcester 24CDi Specifications

General IconGeneral
Model24CDi
Output24 kW
Efficiency RatingA
Max Working Pressure3 bar
Central Heating Flow Temperature Range30 - 80 °C
Fuel TypeNatural Gas
MountingWall Mounted

Related product manuals