Page #29 background imageLoading...
Page #29 background image
Supplied By www.heating spares.co Tel. 0161 620 6677
29
The overheat thermostat can be
reset by pressing the reset button,
but if it trips immediately or on a
regular basis a serious problem has
occurred therefore contact your
installer
Reset thermostat
Overheat Thermostat Check
Pump Check
Fan Check
Does button hold in?
Secure Connector
Secure Connector
Faulty pump
Is pump connector
secure on the PCB (X3)?
Is fan connector
secure on the PCB (X4)?
Is mains present at the
pump connector
(X3 pins 1 & 2)?
Is mains present at the
fan connector
(X4 pins 1 & 2)?
ATTACH to heat
exchanger
Is capillary broken?
Ensure appliance is
cool and retest
Replace overheat
thermostat
Is capillary firmly
ATTACHED
to exchanger?
GO TO
CHECK I
GO TO
CHECK O
GO TO
CHECK L
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
YES
NO
NO
NO
Faulty Harness
Faulty fan
YES
Mains at fan
NO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester 24I RSF and is the answer not in the manual?

Worcester 24I RSF Specifications

General IconGeneral
Model24I RSF
CategoryBoiler
Output24 kW
Fuel TypeNatural Gas
MountingWall-mounted
Warranty2 years
TypeRegular
Hot Water Flow Rate11 L/min

Related product manuals