Sound pressure level L
pA
: 77.8 dB (A)
Uncertainty K
pA
: 3 dB (A)
Device weight: 41.5 kg
Article number: 94243
The noise emission data were determined in accordance with EN ISO 2151:2008.
The noise level may increase by
1 to 10 dB (A) depending on the environment where the compressor is set up.
• The compressor fulfils the requirements of EN 61000-3-11 and is subject to con-
ditional connection. This means it is not permitted to use the device with freely
selected connection points.
• In the event of unfavourable grid conditions, the compressor could produce tem-
porary fluctuations in voltage.
• The compressor is only designated for use with connection points that
a) do not exceed a maximum permissible grid impedance Z
max
< 0.322 Ω,
or
b) have a continuous grid current-carrying capacity of at least 100 A per phase.
• Make sure that the connection point which the compressor is to be connected to
fulfils one of the two specified requirements a) or b). If necessary, consult your
energy utility.