BWS platform scales Technical Manual
- 15 -
600 / 1200 / 2400 / 4800 / 9600
Pr
To set the parity
Options:
7 e1 / 7 o1 / 8 n1
Ptype
To set printer model
Options:
TM220 : set the Tscale printer tm220
Lp50 : Set the Tscale printer LP-50
TM295 : set the Tscale printer tm295
LAB
P 2 mod
Si g r
To select single range operation
Count
To check internal counts
Deci
To set decimal points
Div
To set increment
Cap
Set Capacity
Cal
Calibration
gra
Gravity
Dual 1
To select dual range - mode 1
Note: Once active second interval (div 2), Then second
interval will work until display return to zero
Count
To check internal counts
Deci
To set decimal points
Div
Di v 1
To select first division
Di v 2
To select second division
Cap
Cap 1
To select first capacity
Cap 2
To select second capacity
Cal
Calibration
gra
Gravity
Dual 2
To select dual interval - mode 2
Note: First interval will active in CAP 1
Second interval will active in CAP 2
Count
To check internal counts
Deci
To set decimal points
Div
Di v 1
To select first division
Di v 2
To select second division
Cap
Cap 1
To select first capacity
Cap 2
To select second capacity
Cal
Calibration
gra
Gravity
P3 oth
Lock
To set keypad lock