Step 3: Microphone/Headset. If only one radio is installed, use the primary mic/headset
port. If two radios are installed, use primary mic/headset for transceiver system
#1 and secondary mic/headset for transceiver system #2. If only one mic/headset
port is available on the audio panel, use the primary mic/headset port and
configure the C-5000 to operate in “single mic mode”.
Step 4: Panel Lighting. Select the input pin on P500 for the desired backlighting. Options
are 28 Vdc (pin 50) or 5 Vdc/5vrms (pin 8).
Step 5: System Wiring. Based on steps 1-5, choose the wiring diagrams from this section
that apply to your configuration. Note that if you have two RT-5000’s in your
system, copy the wiring illustrated for P501 to P502. In other words, choose the
wiring for each radio and apply it to the appropriate connector.
A. C-5000 System Interface Connector, P500 Wiring Considerations
(1) P500 Connector
Figure 4-2 P500 Connector