149
Noise / vibration information
Noise value according to EN 15895 and
vibration values (Triax vector sums)
according to EN28927-13:
LPA (Emissions-
sound pressure level)*
dB(A) 88
LWA (sound power level)* dB(A) 101
K (Uncertainty in the speci-
ed sound level)
dB(A) 3
Operating method: Fastening of nails,
main grip
Vibration emission value*
a
h
m/s² 5,4
Measurement uncertainty K m/s² 1.4
Values may vary: The working environment, the
workpiece support, the workpiece, the pressing
force, etc. inuence the noise formation at the place
of use and the eects of vibration on the object. The
vibration emission value specied in this information
sheet was measured in accordance with a stan-
dardised test detailed in EN28927-13:2019 and
can be used for a comparison between two devices.
It can be used for a provisional assessment of the
exposure.
Warning
The specied vibration emission value
relates to the main application of the
device. If, however, the device
is used for other applications with other accessories
or is used despite being poorly maintained, the
vibration emission may vary. This could signicantly
increase the exposure level over the overall operat-
ing period.
An estimation of the vibration strength should also
take into account how often the device is switched
o or over what period of time it is running but not
really in use. This could signicantly decrease the
exposure level over the overall operating period.
Additional safety precautions for the protection of
the operating person against the eects of vibration
must be taken into consideration, e.g. maintenance
of the device and the equipment, keeping warm of
the hands, organisation of the workow.
Declaration of Conformity
We declare under our sole responsibility that this
product conforms to the following standards and
directives:
Standards
• EN ISO 11148-13:2018,
in accordance with the regulations stipulated in the
directives:
EC Directive
• 2014/30/EU
• 2011/65/EU
• 2006/42/EC.
Technical documentation at:
Adolf Würth GmbH & Co. KG, Abt. PFW
A. Kimmig Dr.-Ing. S. Beichter
Section Head, Power Head of Quality
Tools and Systems, Authorized Signatory
Authorised Signatory
Adolf Würth GmbH & Co. KG,
Reinhold-Würth-Straße 12 – 17,
74653 Künzelsau, GERMANY
Künzelsau, 07.01.2021