Xantrex XC Series and BC Series Battery Charger
4 975-0191-01-01
3. The remote display will scroll the following information, in order, on Bank 2 and
then Bank 3:
Highest priority charger fault or warning (if present)
Highest priority battery fault or warning (if present)
Battery voltage
Amp-hours used is not available for Bank 2 or Bank 3.
4. After running through the sequence once, the display will switch itself off. Press the
ON/STANDBY switch to show the sequence again at any time until AC is enabled.
Notice of Copyright
Easy Shunt™ Installation Instructions © August 2005 Xantrex International. All rights reserved.
Warranty
This product has a 24 month limited warranty from the date of first sale which covers defects in workmanship and materials.
Retain proof of purchase. For full details on this limited warranty visit our website at www.xantrex.com or call
1-800-670-0707.
It is important that you read the limited warranty as it restricts your legal rights. If you are not satisfied with the limited
warranty you may return this product to Xantrex with 30 days of the date of purchase for a full refund.
Date and Revision
August 2005 Revision C
Part Number
975-0191-01-01
Contact Information
Phone: 1 800 670 0707 (toll free North America)
+34 93 470 5330 (Europe)
1 360 925 5097 (direct and rest of world)
Fax: 1-800 994 7828 (toll free North America)
+34 93 473 6093 (Europe)
1 360 925 5143 (direct and rest of world)
Email: customerservice@xantrex.com (North America and rest of world)
support.europe@xantrex.com (Europe)
Web: www.xantrex.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex XC Series and is the answer not in the manual?

Xantrex XC Series Specifications

General IconGeneral
Input Frequency50/60 Hz
CoolingFan-cooled
DimensionsVaries by model
WeightVaries by model
Output Voltage12/24 VDC
Battery TypeAGM, Gel
Temperature CompensationYes
Number of Stages3-stage
Efficiency85%
Operating Temperature-20°C to 50°C
Protection FeaturesOver voltage, Over current

Related product manuals