Owner’s Manual
Xantrex
Digital echo-charge
Battery Charger
Digital
echo-charge

Questions and Answers

  • J
    Jason AllenJul 31, 2025
    Why is my Xantrex Digital echo-charge Battery Charger starter battery not charging?
    • E
      ejohnsonJul 31, 2025
      If your Xantrex Battery Charger's starter battery isn't charging, there might be a voltage difference issue. If the voltage difference between the house and starter battery exceeds 2 volts, the charge current will be reduced. If it's greater than 10 volts, the device will shut off, and the green LED will blink. Also, inspect the connections to both battery banks, check the fuses, and ensure the ground connection is secure.
  • R
    riceericAug 7, 2025
    What to do if Xantrex Digital echo-charge Battery Charger LED is red?
    • A
      Adrian HunterAug 7, 2025
      If the LED on your Xantrex Battery Charger is red, it indicates a thermal shutdown. Ensure the Digital echo-charge has sufficient airflow and ventilation. Also, check the battery connections to resolve this issue.
  • R
    ryanschaeferAug 16, 2025
    How to fix Xantrex Digital echo-charge Battery Charger when LED is off?
    • N
      Nicole BarnettAug 16, 2025
      If the LED on your Xantrex Battery Charger is off, check the fuse in the red wire and verify the ground connection.
  • W
    williampowellAug 23, 2025
    Why is the LED flashing green on my Xantrex Battery Charger?
    • H
      Hannah CastroAug 23, 2025
      The LED on your Xantrex Battery Charger flashes green when the house battery voltage is below 13.0 volts DC or above 17 volts DC, or when the difference between the house battery and the starter battery exceeds 10 volts DC.

Summary

Xantrex Digital echo-charge Battery Charger

SAFETY SUMMARY

Fuse Replacement

In-line fuse must be replaced with the same type and rating by an authorized service center or the factory.

Servicing

Do not open the unit; refer all service to qualified personnel due to risk of electric shock.

INTRODUCTION

Included Components

The Digital echo-charge unit includes wire sets, an in-line fuse, and the owner's manual.

THINGS YOU SHOULD KNOW

Battery Connection Guidelines

Use deep-cycle batteries, connect similar batteries, use proper cables, and do not mix battery banks.

BEFORE YOU BEGIN

Needed for Installation

Lists required tools and materials for installation, including screwdrivers, wire cutters, mounting screws, and wire.

INSTALLATION PRECAUTIONS

Mounting Location

Mount vertically in a well-ventilated area, near batteries, away from moisture, dust, and flammable fumes.

Pre-connection Safety

Disconnect all charging sources before making connections; ensure no charging voltage is present.

INSTALLATION

Battery Connections

Connect ground wire to negative battery, starter battery wire to positive terminal, and house battery wire to positive terminal.

Post-connection Operation

Turn charger ON after connections. Green LED indicates house battery and ground connected; charging begins with starter battery connection.

OPERATION

Automatic Switching and Voltage Limiting

Switches ON above 13.0/25.5V (steady green LED) and OFF below, limiting output voltage to 14.4/28.8V.

Charge Current Graph

Graph shows the relationship between voltage differential and charge current for the echo-charge.

Thermal Shutdown and LED Indicators

Elevated temperature can cause red LED and shutdown; unit resets when temperature cools.

TROUBLESHOOTING

Red LED (Thermal Shutdown)

Check airflow, ventilation, and battery connections for thermal shutdown issues.

Starter Battery Not Charging

Check voltage difference, battery connections, and fuses if the starter battery is not charging.

LED is Off

Check the fuse in the red wire and the ground connection if the LED is off.

LED Flashing Green

Check house battery voltage and voltage difference between batteries if LED is flashing green.

GLOSSARY

Key Battery Terms

Defines terms like AGM Battery, Ah Capacity, Current, Cycle, and DC.

Electrical Terminology

Defines terms like AC, Ampere, Ampere-hour, and AWG.

WARRANTY

What does this warranty cover?

Covers defects in workmanship and materials for 12 months from purchase date. Transferable to subsequent owners.

How do you get service?

Contact merchant or Xantrex directly for troubleshooting or warranty service. Provide product details and proof of purchase.

What does this warranty not cover?

Excludes normal wear, installation costs, misuse, neglect, improper installation, or unauthorized repairs.

Disclaimer

States warranty is sole and exclusive, in lieu of all other warranties, express or implied.

Return Material Authorization Policy

Details requirements for returning products, including RMA number, prepaid shipping, and proof of purchase.

Return Procedure

Instructions for safely packaging, including RMA, return address, contact number, and description of the problem.

SPECIFICATIONS

Model Specifications (12 V;24 V)

Table detailing input voltage, output ON/OFF voltages, charge current, reverse current, and voltage limiting.

Protection Features

Lists protection features including reverse polarity, input voltage limits, and thermal protection.