Input Frequency | 50/60 Hz |
---|---|
Cooling | Fan-cooled |
Dimensions | Varies by model |
Weight | Varies by model |
Output Voltage | 12/24 VDC |
Battery Type | AGM, Gel |
Temperature Compensation | Yes |
Number of Stages | 3-stage |
Efficiency | 85% |
Operating Temperature | -20°C to 50°C |
Protection Features | Over voltage, Over current |
Switch off devices, disconnect negative battery terminal from Bank 1.
Connect the D-shaped cutout end of the shunt to the negative battery stud.
Loosen nut on shunt terminal, adjust bolt to contact battery case for support.
Attach removed wires to the new load shunt terminal and tighten nuts.
Route the sensor cable and plug it into the Bank 1 connector on the charger.
Connect the battery positive ring connector to the battery positive terminal.
AC power must be disconnected; Bank 1 must reach float or rest stage for accurate usage gauge.