Fault Codes - Oversized High Capacity Feeder (Trays 8 and 9)
The OHCF fault codes below may pertain to a specific tray of the feeder. If you experience
these fault codes frequently, you should follow the procedure on how to replace the
feed rolls (Replacing the Bypass Tray Feed Rolls for the OHCF (Trays 8 and 9) and
Replacing the OHCF Feed Rolls for the OHCF (Trays 8 and 9)).
Recommended SolutionPossible CauseFault CodeFault Area
1. Fan the paper to eliminate pa-
per adhesion (especially in high
humidity or high temperature
environments).
2. Clean the Bypass Tray feed, re-
tard, and nudger rolls with a
damp cloth.
3. Replace feed rolls (feed, retard,
nudger); refer to Replacing the
Bypass Tray Feed Rolls for the
OHCF (Trays 8 and 9).
4. If problem persists, Call for ser-
vice.
Repetitive misfeeds or
multifeeds
178-120, 078-
125, 078-126,
078-127
Bypass (Tray
5)
Perform the following in this order:
1. Remove or clear any jammed
paper.
2. Replace and fan the paper in
tray.
3. Replace the OHCF Feed Rolls;
refer to Replacing the OHCF
Feed Rolls for the OHCF (Trays
8 and 9).
Pre-registration sensor
jam; during paper
transportation, feed
sensor is not turned on
within period of time
paper is transporting
from tray
178-100, 178-
101
Tray 8
178-103Trays 5 (By-
pass), 8, and
9
Xerox
®
Versant
®
2100 Press10-18
User Guide