Xtreme Power Conversion Corporaon
C60 User’s Manual
Page 5
Uninterrupble Power Supply
Indicators & Alarm Condions
Condion Visual Indicator Alarm
AC mode Green LED illuminated No Audible Alarm
Baery mode Green LED ashes every 10 seconds
Audible Alarm sounds every 10
seconds
Low baery mode Green LED ashes every 1 second
Audible Alarm sounds every 1
second
Fault Red LED is illuminated Audible Alarm is connuous
Overload
Audible Alarm sounds every 0.5
seconds
IMPORTANT SAFETY INSTRUCTIONS: (SAVE THESE INSTRUCTIONS)
CAUTION! (UPS having Internal Baeries): Risk of electrical shock – Hazardous live parts inside this unit are ener‐
gized from the baery supply even when the input AC power is disconnected.
CAUTION! (No User serviceable Parts): Risk of electrical shock, do not remove cover. No user serviceable parts
inside. Refer servicing to qualied service personnel.
CAUTION! (Non‐isolated Baery supply): Risk of electric shock, baery circuit is not isolated from AC input, haz‐
ardous voltage may exist between baery terminals and ground. Test before touching.
WARNING! Unit intended for installaon in a controlled environment.
CAUTION! Do not dispose of baeries in a re, the baery may explode.
CAUTION! Do not open or mulate the baery, released electrolyte is harmful to the skin and eyes.
CAUTION! A baery can present a risk of electric shock and high short circuit current. The following precauon
should be observed when working on baeries:
Remove watches, rings or other metal objects.
Use tools with insulated handles.
To reduce the risk of electric shock, disconnect the UPS from the main supply before installing a computer inter‐
face signal cable. Reconnect the power cord only aer signaling interconnecons have been made. Servicing of
baeries should be performed or supervised by personnel with knowledge of baeries and the required precau‐
ons. Keep unauthorized personnel away from baeries.
The instrucons contained within this safety manual are deemed important and should be closely followed at all
mes during installaon and follow‐up maintenance of the UPS and baeries.
CAUTION: The unit has a dangerous amount of voltage. If the UPS indicator is on, the unit’s outlets may have
a dangerous amount of voltage even when not plugged into the wall outlet because the baery may connue to
supply power. Care should be taken to undertake installaon indoors, free from electrically‐conducve parcles
which are under temperature and humidity control, in order to reduce the risk of electric shock. It is best to dis‐
connect the device using the power supply cord. Ensure that the equipment is placed in a posion near the outlet
where easily accessible. All servicing on this equipment must be carried out by qualied service personnel. Before
conducng any maintenance, repair, or shipment, rst ensure that everything is turned o completely and discon‐
nected.