EasyManuals Logo

XtremeAIR Ultra Series User Manual

Default Icon
14 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
www.XtremeAirUsa.com PAGE
11
E. Adjusting the timer function:
1. While the blower (motor) is not running, touch and hold Decrease Value button over 3 seconds to
enter timer mode.
2. Adjust to desired period of delay off timer by touching Increase Value or Decrease Value button
(minimum 1 minute to maximum 15 minutes). This setting will be saved immediately.
F. Activating the timer function:
* While the blower (motor) is running, touch and hold Power button for over 3 seconds to activate delay
off timer. Power-off delay indicator will light up and power-off delay digital timer will begin to
countdown, when it reaches zero, the blower (motor) will shut down.
G. To clear cleaning reminder:
When blower (motor) starts to rotate, cumulative running time will be shown in Power-On Elapsed
Digital Timer. This timer icon flashes when 30 hours is up and reminds user to clean the baffle filters.
After cleaning the filters and when the motor is not in use, touch and hold (+) Increase Value button
over 3 seconds to reset the timer. Please note that turning off the system will not reset the Power-On
Elapsed Digital Timer.
F. AUTOMATIC SHUT OFF:
MACHINE WILL AUTOMATICLY SHUT OFF AFTER APPROX. 2 ½ HOURS (FOR THOSE
MANUFACTURED AFTER AUGUST 2012 ONLY)
3. TYPE 3: SOFT PRESS BUTTON CONTROL (For All Ultra Series)
SPECIFICATION:
Body Design Seamless Stainless Steel, Satin Finish
Power Rating 120V/60Hz (USA & Canada standard)
General Input Power 184W (90W + 2x2W)
Motor Input Power 90 W each
Ampere 1.70 A
Levels Of Speed Control 4 Levels
Airflow (Q/L/M/H) 280CFM / 460CFM / 670CFM / 900CFM
Noise Level (Q/L/M/H) 1.2Sone(43dB) / 2.8Sone(55dB) / 5.0Sone(63dB) / 6.5 Sone(67dB)
Number Of Motors 2 Motors
Motor Type Single Chamber Ultra Quiet
Fan Type Centrifugal Squirrel Cage
Filtration Type Heavy Duty Stainless Steel Baffle Filter
Illumination LED light, 2W Maximum
Venting Size Top, 8 inches Round
Interference Protection Radio Frequency Interference Protected
Note
Specification subject to change without notice, contact your local reseller for details.
A. Activating Normal Blower Function
Press (2) for lowest speed
Press (3) for medium speed
Press (4) for highest speed
B. To turn off the power:
Press (1)
C. To turn the light ON/OFF:
Press (5) once to turn on, press again to turn off
11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the XtremeAIR Ultra Series and is the answer not in the manual?

XtremeAIR Ultra Series Specifications

General IconGeneral
BrandXtremeAIR
ModelUltra Series
CategoryVentilation Hood
LanguageEnglish

Related product manuals