13
CABLE CHART
Mains Lead Pump terminal
board
L1 brown/(red*) U1
L2 blue/alt. grey (white*) W1
L3 black (black*) V1
Earth (ground) yellow/green
Groundcheck yellow*)
(GC)
Stator leads 460V-Y SER connection:
Stator lead Pump terminal
board
U1, red U1
W2, black V2
V1, brown V1
U2, green W2
W1, yellow W1
V2, blue U2
V5, brown U2
W5, yellow V2
U5, red W2
Control Cable lead
T1 T1 black /orange*
T2 T2 black/blue*
Mains Lead Pump terminal
board
L1 brown/(red*) U1
L2 blue/alt. grey (white*) W1
L3 black (black*) V1
Earth (ground) yellow/green
Groundcheck yellow*)
(GC)
Stator leads 230V-Y// connection:
Stator lead Pump terminal
board
U1, red U1
U5, red U1
V1, brown V1
V5, brown V1
W1, yellow W1
W5, yellow W1
U2, green W2
V2, blue U2
W2, black V2
* SUBCAB AWG
10013a
SUBCAB
SUBCAB
GC
GC
T1
T2
W2 V2U2
L2 L3 T1 T2L1
GC
3~
V1
W1
T2
U1
L1
T1
V1
U1
U2
W1V5
T1 T2
460V Yser.
U5
V2
W5
W2
L3L2
10012a
SUBCAB
SUBCAB
GC
GC
T1
T2
W2 V2
U2
V1 W1
T2
U1
L1
T1
V1
U1
U2
W2
W1
V2
W5U5
V5
230V Y//