EasyManua.ls Logo

Xylem Flygt 3085 - Data Plate Interpretation; General data plate explanation; Approval plates

Xylem Flygt 3085
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
Approval plates
These approval plates apply to an explosion-proof submersible Flygt pump.
The plates are used together with the general data plate on the pump.
DATA PLATE INTERPRETATION
FM: Factory Mutual
Class I Div. I Grp C and D
Class II and III Div. I Grp E, F and G
A Approval
B Approval authority + Approval Number
C Approval for Class I
D Approved drive unit
E Stall time
F Starting current / Rated current
G Duty class
H Duty factor
I Input power
J Rated speed
K Controller
L Additional information
M Max. ambient temperature
N Serial number
O ATEX marking
D
A
N
K
L
M
CB
F
E
G
I
J
H
O
EN: European Norm
ATEX Directive
EN 50014, EN 50018, EN 1127-1
II 2 G EEx dII T4
General data plate
A Serial number
B Product code + Number
C Curve code / Propeller code
D Country of origin
E Product number
F Additional information
G Phase; Type of current; Frequency
H Rated voltage
I Thermal protection
J Thermal class
K Rated shaft power
L International standard
M Degree of protection
N Rated current
O Rated speed
P Max. submergence
Q Direction of rotation: L=left, R=right
R Duty class
S Duty factor
T Product weight
U Locked rotor code letter
V Power factor
X Max. ambient temperature
A
M
L
N
V
U
TRSQPO
I
JK
H
G
F
E
D
B
C
X
EN approval for the Cable entry
Certificate number: INERIS 03ATEX9008 U
II 2 G or IM2 EEx d IIC or EEx d I

Related product manuals