EasyManua.ls Logo

Yale 7100 Series

Yale 7100 Series
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Copyright ©2018, 2020, 2021, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in
whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
For technical support contact Yale
®
at 800.438.1951 x5033 or support@yalelocks.com
20
Delayed Egress
Installation Instructions
7100, 7200 Series Exit Device
8094700162000 04/21
14 Non-ElectroLynx Door Prep
Figure 8
Refer to Figure 8 for non-ElectroLynx Door preparation.
NOTE:
Do not scale drawing.
Dimensions are in inches (") and millimeters (mm).
LHR H.M. opening shown. Details are typical for all opening materials (both hands).
This preparation is an addition to preparation shown on device template.
See device template to locate centerline.
Shields for wiring access recommended for insulated and composite doors.
Locate and prepare wiring access holes when installing device.
Vertical
Reference
Horizontal
Reference
Hinge Edge Detail
INSIDE FACE OF DOOR
Clear Channel Access
Required for Wire
Connection
Hinge
1" (25mm) Dia.
(Wiring Access)
Horizontal Reference
Device Center line
(See Note 5)
Exit Device End Clamp Mounting
Holes (For reference only)
HINGE EDGE DETAIL
Hinge Edge
Of Door
5/16" Ref
(8mm)
5/8" Ref
(16mm)
A
1-1/4" Ref
(32mm)
Exit Device
7200 Serie
s
7100 Series
Dim. A
1-11/16" (43mm)
2-5/16" (59mm)
Conducting Hinge or
Approved Power Transfer
(made by other manufacturers)

Related product manuals