Table 15. Proc_Cal_013: Aux 3 Dir B Valve Output Threshold (Continued)
Information:
Pressure Method: Perform Actions 1, 2, 3, 4, and 6.
Visual Method: Perform Actions 2, 3, 5, and 6.
Information: Leave truck running at idle after performing Proc_Cal_002.
Action 1: With the truck running, note the pressure reading (standby pressure).
Action 2: Activate Lift Control to Position Attachment 0.6 m (2 ft) up
with no load on the forks/attachment. Activate the Aux 3 control to
position the function in the middle of the range.
You Will See: Main Menu
Passwords
Step 1: Press or
Until You See: Main Menu
Calibrations
Step 2: Press * One Time
You Will See: Calibrations
Lift Valve Output
Step 3: Press or
Until You See: Calibrations
Aux 3 Output Dir B
Step 4: Press * One Time
You Will See: Aux 3 Output Dir B
Press * at Creep
A. E-HYD CONTROL LEVERS
1. LIFT/LOWER
DIRECTION LIFT ↓
DIRECTION
LOWER ↑
2.TILT
DIRECTION BACK
↓
DIRECTION FWD
↑
3.*AUX 1 OR AUX
2
DIRECTION A ↑
DIRECTION B ↓
4.*AUX 2 OR AUX
3
DIRECTION A ↑
DIRECTION B ↓
5.*FOURTH
LEVER
6.*THIRD LEVER
7.SEAT ARMREST
*AUX 2 IS IN THE FOURTH LEVER LOCATION EXCEPT AS FOLLOWS: WITH 5 FUNCTION VALVE WITH CLAMPING ATTACHMENT,
AUX 2 IS IN THE THIRD LEVER LOCATION.
Proc_Cal_013: Aux 3 Dir B Valve Output Threshold 8000 YRM 1134
38 Confidential/Proprietary - Do Not Copy or Duplicate