Table 20. Proc_Cal_016B: Transmission Valve Calibration (Continued)
NOTE: Keep park brake applied, full service brake applied, and
full accelerator applied during entire time that automated transmis-
sion valve calibration is occurring. If you release the service brake
at any time during L2 calibration, the calibration will start over from
the beginning.
Press * One Time
You Will See: Xmsn Oil Temp
xxx°
Watch display countdown. When completed successfully.....
The engine will go to idle and you will see for approximately 5 mi-
nutes:
You Will See: Calibrate Xmsn Valve
Xmsn Calibration 0
Watch display. When completed successfully..... You will see
for approximately 5 minutes:
You Will See: Calibrate Xmsn Valve
Xmsn Calibration 1
Watch display. When completed successfully..... You will see
for approximately 5 minutes:
You Will See: Calibrate Xmsn Valve
Xmsn Calibration 2
Watch display. When completed successfully..... You will see
for approximately 5 minutes:
You Will See: Calibrate Xmsn Valve
Xmsn Calibration 3
Watch display. When completed successfully..... You will see
for approximately 5 minutes:
You Will See: Calibrate Xmsn Valve
Xmsn Calibration 4
Watch display. When completed successfully..... You Will See: Calibrations
Calibrate Xmsn Valve
Perform Proc_Cal_003: Save and Exit.
8000 YRM 1134 Proc_Cal_016B: Trans. Valve Calibration-Electronic and Electronic Extended
Function
Confidential/Proprietary - Do Not Copy or Duplicate 51

Table of Contents

Other manuals for Yale GP120VX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yale GP120VX and is the answer not in the manual?

Yale GP120VX Specifications

General IconGeneral
BrandYale
ModelGP120VX
CategoryForklifts
LanguageEnglish

Related product manuals