MX-100B
8. Adjusting the mute unit
[Tape tension adjustment]
Adjust the tape holder to a position where the
tape is not excessively loose or tight when the
soft mode is off, and fasten it in place.
[Adjusting the soft sensor]
Adjusting the normal mode switch
Adjust the screw
to open the normal mode
switch in the normal mode [VOL.0 ~ - 8].
17
Adjusting the soft mode switch
Set the volume to the soft mode
[VOL.
-
9
~-
10
].
And
adjust
the
screw
to
the open the soft mode switch when the
hammer blow distance is 1 7mm+/-3 in soft
mode.