EasyManua.ls Logo

Yamaha EF6600DE - G.F.C.I. Receptacle Safety and Test; G.F.C.I. Receptacle Test Procedure

Yamaha EF6600DE
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 11 –
1
2
763-083
3
763-060
G.F.C.I. RECEPTACLE
TO REDUCE THE CHANCE OF ELECTRICAL
SHOCK:
9 Do not attempt to operate electric devices if
the ground fault circuit interrupter reset button
pops out repeatedly during use.
9 Test the ground fault circuit interrupter during
the pre-operation checks according to the
maintenance instructions on page 35.
9 Remember that only receptacle labeled “GFCI”
have ground fault circuit interrupter protec-
tion.
The G.F.C.I. (Ground Fault Circuit Interrupter) shuts
off power to the protected receptacles if a ground fault
(electrical leak) is detected.
If the reset button pops out, the electric devices con-
nected into the receptacle may be faulty. If this hap-
pens, check the electric devices carefully. If the elec-
tric devices appears to be in good condition, press the
reset button firmly until a click is heard. This will
restore power. If the reset button pops out again, dis-
connect all the electric devices immediately. Have the
electric devices inspected and repaired by a qualified
repairperson before attempting to use them again.
1 G.F.C.I. (Ground Fault Circuit Interrupter)
2 Reset button
3 Pops out
WARNING
7CC-F8199-15-1 11.2.21 15:55 Page 11