– 18 –
Electric Starting Model:
(For EF6600DE)
4. Push the starter switch to start the engine.
1 Starter switch
9 Take your hand off the switch immediately
after the engine starts.
9 If the engine fails to start, release the switch,
wait a few seconds, then try again. Each
attempt should be as short as possible to pre-
serve the battery. Do not crank the engine
more than 5 seconds on any one attempt.
Manual Starting Model:
(For EF6600D)
4. Turn the choke lever to “1”.
1 Choke lever
TIP
The choke is not required to start a warm engine. Turn
the choke lever to the original position.
5. Pull slowly on the recoil starter until it is engaged,
then pull it briskly.
6. After the engine starts, warm up the engine until
the engine does not stop when the choke lever is
returned to the original position.
1 Original position
7CC-F8199-15-1 11.2.21 15:56 Page 18