24
R-1330/NS-BP400
R-1330/NS-BP400
PS1xxx
NOPRT 1.VER:068/G
CAUTION!
Using this product with the protection function disabled
may cause damage to itself. Use special care when us-
ing this mode.
注意!
プロテクションを解除した状態でのダイアグモードは、
危険な状態でもプロテクションが作動しないため、動作
させると、機器を破壊することがあります。このモード
を使用する場合は十分注意してください。
When there is a history of protection function:
When there is a history of protection function due to
abnormal voltage in the power supply section
For details of protection functions, refer to the main menu
No. 4-1 PS1.
● Canceling Self-Diagnostic Function
1. Before canceling self-diagnostic function, execute
setting for FACTORY PRESET of main menu No. 3
(Memory initialization inhibited or Memory initialized).
* In order to keep the user memory stored, be sure
to select PRESET INH (Memory initialization inhib-
ited).
2. Press the “ON/STANDBY, OFF” switch of this unit to
turn off the power.
● Display provided when Self-Diagnos-
tic Function started
The FL display of this unit displays the protection function
history data then the main menu (sub-menu FIRMWARE
VERSION/DESTINATION of main menu No. 1 VER/DEST/
SUM) a few seconds later.
When there is no history of protection function:
● ダイアグの解除
1. ダイアグを解除する前に、メインメニュー No.3 の
FACTORYPRESET(メモリーの初期化禁止 /またはメ
モリーの初期化)の設定をします。
※ ユーザーメモリーを保持したい場合は、必ず
PRESETINH(メモリー初期化禁止)を選択してく
ださい。
2. 本機の “ON/STANDBY、OFF” スイッチを押して電源
を切ります。
● ダイアグ起動時の表示
本機の FLディスプレイにプロテクション履歴情報が
表示されます。数秒後、メインメニュー No.1「VER/
DEST/SUM」のサブメニュー「1-1FIRMWAREVERSION/
DESTINATION」が表示されます。
プロテクション履歴がない場合:
プロテクション履歴がある場合:
電源部の電圧異常によるプロテクション履歴がある場合
After a few seconds /
数秒後
A/D conversion value of voltage /
電圧の A/D 変換値
プロテクションの詳細は、メインメニュー No.4-1PS1 を
参照してください。
Main menu display /
メインメニュー表示
Opening message /
オープニング表示
Firmware version Destination