25
R-1330/NS-BP400
R-1330/NS-BP400
PSDxxx
THMxxx
History of protection function
When the protection function has worked, its history is
stored in memory with a backup. Even if no abnormality
is noted while servicing this unit, an abnormality which
has occurred previously can be defined as long as the
backup data has been stored.
The history of the protection function is cleared when
self-diagnostic function is cancelled by selecting
PRESET RSRV (Memory initialized) of main menu No.
3 or when the backup data is erased.
● プロテクションの履歴
プロテクションが働いた場合、履歴をバックアップ
して記憶しています。修理のときに異常が認められ
なくても、バックアップが残っていれば、お客様の
ところで起きた異常を区別できます。
メインメニュー No.3 PRESETRSRV(メモリーの
初期化)を選んでダイアグを解除した場合、または
バックアップが消えた場合に、プロテクションの履
歴はクリアされます。
When there is a history of protection function due to
abnormal voltage in the digital amplifier section.
When there is a history of protection function due to
abnormal temperature.
For details of protection functions, refer to the main menu
No. 4-2 DAMP.
デジタルアンプ部の電圧異常によるプロテクション履歴
がある場合
温度異常によるプロテクション履歴がある場合
A/D conversion value of voltage /
電圧の A/D 変換値
A/D conversion value of voltage /
電圧の A/D 変換値
プロテクションの詳細は、メインメニュー No.4-2DAMP
を参照してください。