Notes)
Applying the power to this unit without correcting the abnormality can be dangerous and cause additional
circuit damage. To avoid this, if “PS” and “DC” protection function works 3 times consecutively, the power will
not turn on even when the “MAIN ZONE
key is pressed. In order to turn on the power again, start up the self-
diagnostic function.
The output transistors in each amplifier channel should be checked for damage before applying power to this
unit.
Amplifier current should be monitored by measuring DC voltage across the emitter resistors for each channel.
Cause: DC output of the power amplifier is abnormal.
Supplementary information: The protection function worked due to a DC voltage appearing at the speaker terminal. A
cause could be a defect in the amplifier.
Turning on the power without correcting the abnormality will cause the protection function to work in 5 seconds and the
power supply will be shut off.
2-2. When the protection function worked due to abnormal DC output.
AD conversion value when the protection function is working
AD conversion value when the protection function is working
Cause: The voltage in the power supply section is abnormal.
Supplementary information: The protection function worked due to a defect or overload in the power supply.
Turning on the power without correcting the abnormality will cause the protection function to work in 1 seconds and the
power supply will be shut off.
2-3. When the protection function worked due to abnormal voltage in the power supply section.
DCPRT:xxxH
PSPRT:xxxL