Requirements for Installation
6. Choose a correct power distribution board or receptacle
Choose a correct power distribution board or receptacle that meets the unit’s rated electric
capacity.
Electric capacity : FO100: AC100 V, 11A
FO200: AC100 V, 16A
FO300: AC100 V, 21A
FO310: AC200 V (Single phase), 11A
FO410: AC200 V (Single phase), 12A
FO510: AC200 V (Single phase), 13.5A
FO610: AC200 V (Single phase), 16A
FO710: AC200 V (Single phase), 18.5A
FO810: AC200 V (Single phase), 21A
NOTE)
There could be the case that the unit does not run even after turning ON the power. Inspect
whether the voltage of the main power is lowered than the specified value, or whether other
device(s) uses the same power line of this unit. If the phenomena might be found, change the
power line of this unit to the other power line.
7. Before/after installing
It may cause injure to a person if this unit falls down or moves by the earthquake and the
impact. etc.. To prevent, take measures that the unit cannot fall down, and not install to busy
place.
Touching the unit may cause a burn during and after the operation. To prevent, take measures
that putting up a notice of operating etc..
8. Handling of power code
Do not entangle the power cord. This will cause overheating and possibly a fire.
Do not bend or twist the power cord, or apply excessive tension to it. This may cause a fire
and electrical shock.
Do not lay the power cord under a desk or chair, and do not allow it to be pinched in order to
prevent it from being damaged and to avoid a fire or electrical shock.
Keep the power cord away from any heating equipment such as a room heater. The cord's
insulation may melt and cause a fire or electrical shock.
If the power cord becomes damaged (wiring exposed, breakage, etc.), immediately turn off the
power at the rear of this unit and shut off the main supply power. Then contact your nearest
dealer for replacement of the power cord. Leaving it may cause a fire or electrical shock.
Connect the power plug to the outlet which is supplied appropriate power and voltage.